Uncertainty of emission measurements for manual and automatic reference methods. Comparison between uncertainty budget approach and inter-laboratory field test approach - Ineris - Institut national de l'environnement industriel et des risques Accéder directement au contenu
Communication Dans Un Congrès Année : 2003

Uncertainty of emission measurements for manual and automatic reference methods. Comparison between uncertainty budget approach and inter-laboratory field test approach

Résumé

The aim of this presentation is to give a comparison of the GUM approach which gives an overall uncertainty calculated through an uncertainty budget and the field approach which gives repeatability and reproducibility uncertainties. Two examples will be shown from the experiences within CEN TC264 WG16 by means of a manual reference method for SO2 and an automatic reference method for NOX.
Fichier principal
Vignette du fichier
2003-062_hal.pdf (826.24 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)

Dates et versions

ineris-00972425 , version 1 (03-04-2014)

Identifiants

  • HAL Id : ineris-00972425 , version 1
  • INERIS : PU-2003-062

Citer

Jean Poulleau, Cécile Raventos, Frans Blank, Lukas Emmenegger, Richard Gould, et al.. Uncertainty of emission measurements for manual and automatic reference methods. Comparison between uncertainty budget approach and inter-laboratory field test approach. Workshop on Quality Assurance Quality Control and Accreditation, May 2003, Prague, Czech Republic. ⟨ineris-00972425⟩